Emergency-Off Switches · Switch Disconnector

Konrak LW30 Isolator Switch

LW30 Emergency-Off Switches — switch disconnector, OFF-ON, 25 A to 100 A

The LW30 range of emergency-off switches and switch disconnectors is designed for the safe isolation of machine tools, distribution panels and switchboards. Available from 25 A to 100 A in 3- and 4-pole versions, with rear-panel, base (DIN-rail) or enclosure mounting and a choice of handles.

25–100 A3P / 4POFF-ONRear panel · Base · EnclosureIEC / EN 60947-3 · GB 14048.3CE
Konrak LW30 switch disconnector
Model LW3025–100 A · 3P / 4P
25–100 ACurrent range
3P / 4PPoles
OFF-ONFunction
3Mounting styles
Mounting & Poles

One switch, several mounting styles

Choose rear-panel, base (DIN-rail) or enclosure mounting, in 3-pole or 4-pole versions. A door-interlock mounting option is also available.

Konrak LW30 isolator switch — Base (DIN-rail) · 3-pole

Base (DIN-rail) · 3-pole

Clips onto a 35 mm DIN rail (EN 50022) — the standard base-mounting version.

Konrak LW30 isolator switch — Panel (rear) · 3-pole

Panel (rear) · 3-pole

Rear-panel mounting through the panel, operated by a knob handle.

Konrak LW30 isolator switch — Base (DIN-rail) · 4-pole

Base (DIN-rail) · 4-pole

4-pole base version for three-phase + neutral or four-wire circuits.

Konrak LW30 isolator switch — Panel (rear) · 4-pole

Panel (rear) · 4-pole

4-pole rear-panel version with knob handle and door-interlock option.

Enclosure mounting (E) is also available across the range. Dimensional drawings for each version are available on request.

Current Range

25 A to 100 A

Six ratings cover the most common industrial isolation duties.

25 AIth
32 AIth
40 AIth
63 AIth
80 AIth
100 AIth
Technical Specifications

LW30 technical data

General specifications
StandardsIEC 60947-3 · EN 60947-3 · GB 14048.3
FunctionOFF-ON switch disconnector
Rated thermal current (Ith)25 · 32 · 40 · 63 · 80 · 100 A
Rated working voltage (Ue)240 V · 440 V
Poles3P · 4P
MountingR = rear panel · B = base (DIN rail) · E = enclosure
ActuatorKnob — types 1 / 2 / 3 (padlock or normal knob)
Utilisation categoriesAC-21A · AC-22A · AC-23A · AC-3
MarkingCE
Utilisation categories — A / kW
ModelAC-23A 240 VAC-23A 440 VAC-3 240 VAC-3 440 V
LW30-2515 / 414 / 7.511.7 / 311.7 / 5.5
LW30-3222 / 5.522 / 1115 / 415 / 7.5
LW30-4030 / 7.530 / 1515 / 415 / 7.5
LW30-6343 / 1143 / 2236 / 1136 / 18.5
LW30-8057 / 18.557 / 3043 / 1543 / 22
LW30-10070 / 2270 / 3757 / 18.557 / 30

AC-21A and AC-22A = rated thermal current (Ith). Values are A / kW (current / rated power).

How to Order

Build your LW30 model code

Configure the switch by current rating, function, poles, mounting and actuator.

LW30-63Series & current
OFF-ONFunction
4Poles (3P / 4P)
BMounting (R / B / E)
2Actuator (knob 1/2/3)
Example:  LW30-63 4 B 2  =  63 A · 4-pole · base (DIN-rail) mounting · knob type 2

Codes shown are a guide based on the Konrak LW30 range. Please confirm the exact code with Konrak sales before ordering.

Key Features

Safe, compact isolation

Switch disconnector OFF-ON

A load-break isolator for the safe isolation of circuits during maintenance.

Three mounting styles

Rear-panel (R), base / DIN-rail (B) and enclosure (E) versions.

3-pole and 4-pole

3P and 4P versions for three-phase and three-phase + neutral circuits.

Choice of handles

Knob actuators in several types — padlockable or normal — plus a door-interlock option.

Utilisation categories

Rated AC-21A, AC-22A, AC-23A and AC-3 up to 100 A.

Lockable for safety

Padlockable knob versions support lock-out / tag-out during maintenance.

Compact & modular

Small footprint for machine tools, distribution panels and switchboards.

Standards compliant

Designed to IEC/EN 60947-3 and GB 14048.3, CE marked.

Applications

Where the LW30 is used

Typical installations where the LW30 switch disconnector provides safe, lockable isolation of the supply.

Konrak LW30 isolator switch - Machine tools

Machine tools

Local isolation of machine-tool power supplies.

Konrak LW30 isolator switch - Distribution panels

Distribution panels

Main isolation for distribution boards and switchboards.

Konrak LW30 isolator switch - Motor circuits

Motor circuits

Load-break isolation of motor and control circuits.

Konrak LW30 isolator switch - General machinery

General machinery

Safe isolation for any industrial machinery.

FAQ

Frequently asked questions

What is the LW30 used for?

It is a switch disconnector (isolator) used to safely isolate circuits — typically machine tools, distribution panels and switchboards — for maintenance and lock-out.

Which current ratings are available?

25 A, 32 A, 40 A, 63 A, 80 A and 100 A (rated thermal current Ith).

Which mounting options are there?

Rear-panel (R), base / DIN-rail (B) and enclosure (E), plus a door-interlock mounting option.

Are 3-pole and 4-pole versions available?

Yes — both 3-pole (3P) and 4-pole (4P) versions are available across the range.

What handles are available?

Knob actuators in several types, in padlockable or normal versions; a door-interlock version is also available.

What are the utilisation categories?

AC-21A and AC-22A (= Ith), AC-23A and AC-3 up to 100 A; see the utilisation table for A / kW at 240 V and 440 V.

What standards does it meet?

IEC 60947-3, EN 60947-3 and GB 14048.3; the range is CE marked.

Need the right LW30 for your panel?

Tell us the current rating, number of poles and mounting style you need — our team will confirm the exact configuration and can supply samples or OEM versions.

Request a Quote Download Datasheet (PDF)
+86-15258472950 Phone davy@konrak.com E-mail Chat on WhatsApp WhatsApp